How signals are captured

Follow the physical chain from neural activity to EEG, MEG, MRI and other sensors.

EEG · Electroencephalography

What it measures

A voltage difference at the scalp, usually tens of microvolts (µV).

  1. 01Aligned cortical pyramidal cells fire synchronous postsynaptic currents
  2. 02These currents act as tiny electrical dipoles
  3. 03Current spreads (volume conduction) through CSF, skull and scalp
  4. 04An electrode measures the resulting voltage vs. a reference
1–10 ms

Temporal resolution

~5–9 cm (19-ch); ~cm with high-density source imaging

Spatial resolution

Non-invasive (scalp contacts)

Invasiveness

high

Portability

$100–$2,000 consumer; $5k–$50k+ research (32–128 ch)

Rough cost

Limitations

  • The skull smears the signal; source localization is non-unique (the inverse problem)
  • Strong eye, muscle, movement, sweat and 50/60 Hz mains artifacts

Modality comparison

ModalityTemporal resolutionSpatial resolutionInvasivenessPortabilitySignal pathRough cost
EEG1–10 ms~5–9 cm (19-ch); ~cm with high-density source imaging○○highDirect neural$100–$2,000 consumer; $5k–$50k+ research (32–128 ch)
MEG~1 ms~3–10 mm (superficial); ~1–1.5 cm (deep)○○noneDirect neural~$3–5 million with shielded room; ~$1.5k–$5k per scan
fMRI1–3 s sampling; BOLD peaks ~5–6 s after activity~2–3 mm at 3T; sub-mm at high field○○noneIndirect / hemodynamic$1.6–3M scanner; $500–$2,000+ per session
fNIRS0.1–1 s useful; responses evolve over seconds~1–3 cm laterally; only ~10–15 mm past the skull○○highIndirect / hemodynamic$15k–$150k research; hundreds–few $k for low-channel
ECoG<1–5 ms~4–10 mm clinical; sub-mm with micro-ECoG●●mediumDirect neural$20k–$100k grid/amp; procedure many tens of $k+
MEA~0.05–1 ms (spike timing)~50–150 µm around a tip●●mediumDirect neural$50k–$250k+ rig/arrays, excluding neurosurgery and long-term care
EMG~1 ms; sampling 1–5 kHzSurface EMG: cm-scale detection volume○○highDirect neural$100–$2k education/wearable; $3k–$30k+ multichannel research